7 Inch Portable Patient Monitor

R12.00 R11.00

Patient Range

Neonate, Paediatric and Adult Patients

Dimension and Weight

Dimension: 192mm(W)*1480mm(H)*91mm(D)
Weight: Standard Configuration < 1.2kg

 

SKU: IBS-PM7 Category:

Description

Performance Specifications:
  • Display: 7” color TFT(diagonal)
  • Rolling and refreshing waveform display
  • Resolution: 800*480
  • Multi displays selectable, including:
    • Standard Display
    • Large-font Display
    • Trend Table Display
    • NIBP Trend Display
    • EGG Full Leads
    • OxyCRG dynamic view Display
  • Trace: 8 waveforms
  • Sweep Speed: 6.25mm/s, 12.5mm/s, 50mm/s
  • Indicators:
    • Alarm indicator light
    • Battery indicator light
    • QRS beep and alarm sound
    • Power indicator light
  • Interface:
    • Parameter cable interface
    • DC Power input socket
    • Network interface
  • Li-ion Battery: Rechargeable, maximum 8 hours for charging, 5.5 hours for continuous working
  • Trend time: 1~96 hours
  • Alarm: User-adjustable High and Low limits 3-level audible and visual alarm
  • Networking: Connected to central monitoring system
Standard Configuration
  • ECG 5 Lead; NIBP; RESP; SpO2; Temp; Lithium Battery
ECG
  • Lead type: 5-lead
  • Input: 5-lead: RA; LA; RL; LL; V
  • Lead selection: I; II; III; aVR; aVL; aVF; V
  • Gain selection: X2.5mm/mV, X5.0mm/mV, X10mm/mV, X20mm/mV
  • Sweep speed: 12.5mm/s, 25mm/s, 50mm/s
  • Heart Rate range: Adult: 15-300bpm; neonate/pediatric: 15-350bpm
  • Accuracy: ±1bpm or±1%, whichever is greater
  • Resolution: 1bpm
  • Filter:
    • Diagnostic mode: 0.05-130 Hz
    • Monitoring mode: 0.5-40 Hz
    • Surgical mode: 1-20 Hz
  • Scalling signal: 1mV±5%
  • Alarm range: 15-350 bpm
  • S-T segment detection:
    • Measurement range: -2.0mV~2.0mV
    • Alarm range: -2.0mV~2.0mV
  • Arrhythmia analysis: YES
  • Pace detection: YES
  • Alarm: YES, audible and visual alarm, alarm events recallable
Respiration
  • Method: Thoracic impedance
  • Sensing leads: Lead I and Lead II are optional (default: lead II)
  • Operation modes: Auto/ Manual
  • Measurement range: Adult:0~120 BrPM; Neonate/Pediatric: 0~150 BrPM
  • Apnea alarm: YES
Temperature
  • Measurement range: 0~50°C (32~122°F)
  • Resolution: 0.1°C
  • Accuracy: ±1°C
  • Channel: One-channel
Standard SpO2
  • Measurement range: 0-100%
  • Resolution: 1%
  • Accuracy:
    • ±2% (70-10Adult/Paediatric)
    • ±3% (70-100%, Neonate)
    • 0-69% unspecified
  • Alarm range: 0-100%
  • Pulse rate:
    • Range: 20-254bmp
    • Resolution: 1bpm
    • Accuracy:±3bpm (non-motion)
    • Alarm range: 0-254bpm
NIBP
  • Method: Automatic oscillometric
  • Operation modes: Manual/Automatic/Continuous
  • Auto measure time: Adjustable
  • Measurement Unit: mmHg/kPa selectable
  • Measurement types: Systolic, Diastolic, Mean
  • Range of systolic pressure:
    • Adult Mode: 40-270mmHg
    • Paediatric Mode: 40-200mmHg
    • Neonatal Mode: 40-135mmHg
  • Range of diastolic pressure:
    • Adult Mode: 10-210mmHg
    • Paediatric Mode: 10-150mmHg
    • Neonatal Mode: 10-100mmHg
  • Range of mean pressure:
    • Adult Mode: 20-230mmHg
    • Paediatric Mode: 20-165mmHg
    • Neonatal Mode: 20-110mmHg
  • Accuracy of blood pressure measurement:
    • The mean error shall be less than ±5mg
    • The standard deviation shall be less than 8mg
  • Over-pressure protection: Double safety protection
  • Resolution: 1mmHg
  • Alarm: Systolic, Diastolic, Mean
  • Resolution: 1mmHg
  • PR from NIBP
  • Measurement range:
    • 40~240bpm
    • Resolution: 1bpm
    • Accuracy: ±3bpm or ±3% whichever is greater
Optional Configurations
EtCO2 (Optional)
  • Measurement range: 0%-13%
  • Accuracy: ±2mmHg(0-40 mmHg), ±5% of reading (41-76 mmHg), ±10% of reading (77-99 mmHg)
  • Accuracy: 2mmHg @<5.0% Co2(at ATPS)
  • Respiration rate: 3-150 rpm±1bpm
NELLCOR SpO2 (Optional)
  • Measurement range: 0-100%
  • Resolution: 1%
  • Accuracy:
    •  ±2%(70-100%,MAX-A,MAX-AL,MAX-N,MAX-P,MAX-I and MAX-FAST sensors)
    • ±2.5% (70-100%, OxiCliq A, OxiCliq N, OxiCliq P and OxiCliq I sensors)
    • ±3% (70-100%, D-YS, DS-100A, OXI-A/N and OXI-P/I sensors)
    • ±3.5% (70-100%, MAX-R, D-YSE and D-YSPD sensors)
    • 0-69% unspecified
  • Alarm range: 0-100%
  • Pulse rate:
    • Range: 20-300bmp
    • Resolution: 1bpm
    • Accuracy:
      • ±3bpm (20-250bpm)
      • 251-300 bpm unspecified
    • Alarm range: 0-254 bpm
MASIMO SpO2 (Optional)
  • Measurement range: 0-100%
  • Resolution: 1%
  • Accuracy:
    • ±2% (70-100%, Adult/Paediatric, non-motion)
    • ±3% (70-100%, Neonate, non-motion)
    • ±3% (70-100%, Adult/Paediatric/Neonate, non-motion)
    • 0-69% unspecified
  • Alarm range: 0-100%
  • Pulse rate:
    • Range: 25-240bmp
    • Resolution: 1bpm
    • Accuracy:
      • ±3bpm (non-motion)
      • ±5bpm (motion)
    • Alarm range: 25-240bpm